HI98143 pH and EC Transmitter with Galvanic Isolated Output
Previous | 3 / 9 | Next |
The HI98143 is part of a family of blind transmitter that can be used in water treatment and hydroponic applications. These meters have inputs for both pH and EC probes. The pH probe input uses a common BNC connector while EC has a direct wire connection for use with Hanna's EC probes that incorporate an NTC sensor for temperature compensation.
The HI98143 is available in four models based on the analog output signal required.
- Blind transmitter for pH and EC (up to 10 mS/cm)
- Choice of analog output in voltage or current
- Powered or loop powered analog outputs
Direct Connection
Direct connection of the probes to the transmitter assures a positive electrical connection with no signal loss. This transmitter is ideal for remote process control applications.
Output Signals
Four models are available, transmitting a 0-1 V, 0-4 V or 4-20 mA signal. The output signals are proportional to the input signals but independent of changes in load or cable capacitance.
Automatic Temperature Compensation
Compensation for the effects of temperature for EC measurements is performed by the transmitters’ Automatic Temperature Compensation circuitry.
Connectivity
The transmitter can be connected to any pH or conductivity controller, recorder, PC or any data monitoring device that accepts 0 to 1 V, 0 to 4 V or 4 to 20 mA input.
Simple Design
Probes connectors, power supply, contacts, and calibration trimmers are easy to reach directly on the front panel
Versatile Use
For in-line applications, the recommended pH electrode is the HI1001 while the conductivity probe is the HI3001. HI1001 is a combined double junction pH electrode with BNC and 3m cable; HI3001 is a 4-ring conductivity probe with platinum sensors and an int
SKU | HI98143-web |
---|---|
Product Name | pH and EC Transmitter with Isolated Output |
Quote Required | Yes |
pH Range | 0 to 14 |
pH Accuracy | ±0.5% f.s. |
pH Calibration | Manual, 2 point, through trimmers |
EC Range | 0 to 10 mS/cm |
EC Accuracy | ±2% f.s. |
EC Calibration | 0 (offset) and 5 mS/cm (slope) trimmers |
EC/TDS Temperature Compensation | Automatic from 0 to 60 ºC |
Temperature Correction Coefficient | ß=2%/ ºC |
Cell Type | 4-ring EC probes |
EC/TDS Probe | Four (ring) pole probe with built in NTC sensor |
Analog Output |
HI98143-01 0-1 V HI98143-04 0-4 V HI98143-20 4-20 mA (passive) HI98143-22 4-20 mA (active) |
Power Supply | 12-24 Vdc |
Environment |
0 to 50 °C (32 to 122 °F); max 95% RH non-condensing |
IP Rating | IP54 |
Dimensions | 160 x 105 x 31mm (6.3 x 4.1 x 1.2”) |
Weight | 280 g (9.9 oz.) |