Visit
Official Website
0

Hanna Instruments (M) Sdn Bhd
11A, Jalan PJS 11/20,
Bandar Sunway,
46150 Petaling Jaya,
Selangor, Malaysia.
+603-5638 9940

Penang Branch Office
Hanna Instruments (M) Sdn Bhd
N0. 303-2-27, Krystal Point,
Jalan Sultan Azlan Shah,
11900 Sungai Nibong,
Penang, Malaysia.
+604-638 4558
+604-645 4558
penang@hannamalaysia.com

Sabah Branch Office
Hanna Instruments (M) Sdn Bhd

No. 4-1, 1st Floor,
Plaza Kingfisher,
Jalan Plaza Kingfisher 5,
Inanam, 88450 Kota Kinabalu,
Sabah, East Malaysia.
088-382 941
088-382 942
sabah@hannamalaysia.com


*HI3810-100 Dissolved Oxygen Chemical Test Kit Replacement Reagents (100 tests)

Previous 4 / 27 Next

Quantity
Add Quotation


Download Files

us_hi3810_0_ghs_usa_1.pdf (280.1 KB)
The HI3810-100 are reagents for the determination of dissolved oxygen (O2) by titration with the HI3810 Dissolved Oxygen Chemical Test Kit. There are enough reagents for approximately 100 tests to be used with Hanna’s test kit. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each packet for traceability.

  • Pre-made reagents for ease of use
  • Prepared with high purity chemicals
  • Marked with expiration date and lot number for traceability

Details

The HI3810-100 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate dissolved oxygen measurements with the chemical test kit. These reagents follow a modified Winkler titration method to determine dissolved oxygen concentration. 

For determination of dissolved oxygen, manganous ions react with oxygen in the presence of potassium hydroxide to form a manganese oxide precipitate. An azide is present to prevent any nitrite ions from interfering with the test. With addition of acid, manganese oxide hydroxide oxidizes the iodide to iodine. Since the amount of iodine generated is equivalent to the oxygen in the sample, the concentration of iodine is calculated by titration of thiosulfate ions that reduce the iodine back to iodide ions. The color change from blue to colorless indicates the endpoint of the titration. The number of milliliters of titrant used to reach the appropriate endpoint will determine the dissolved oxygen concentration as mg/L O2. These reagents are designed to be used with samples that have an expected dissolved oxygen range of 0.0 to 10.0 mg/L O2.

 

Specifications


 
Package bottles
Number of Tests 100
Method modified Winkler

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Messages*  
   

You have 0 items in you cart. Would you like to checkout now?
0 items
Recent Updates
Subscribe Newsletter