BL983329-1 TDS Mini Controller (0 to 999 ppm)
Previous | 11 / 16 | Next |
The BL983329 is a compact, panel mounted, process controller for measuring total dissolved solids (TDS) in a process stream that is within the 0 to 999 ppm (mg/L) range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to supply power to a dosing pump or a solenoid connected to a valve.
*The BL983329 uses a 0.5 conversion factor in which 100 μS/cm = 50 ppm.
Multicolor LED Indicator
LED changes color based on status.
Fire Retardant Casing
For additional safety the controllers outer case is made of fire resistant plastic.
Splash Resistant Cover
A clear plastic cover protects the face panel from dirt and liquids.
Adjustable Dry Contact Dosing Relay
The BL983329 features a dosing relay that is activated when the reading is above a user programmable set point.
Programmable Overdose Protection
For enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.
Relay Control Override
With the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.
Multicolor LED Indicator
Multicolor LED indicator allows an operator to quickly check the status of the controller.
- Green = Meter in measurement mode and reading is below the set point.
- Orange/Yellow = Reading is above the set point and the relay is activated.
- Blinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.
Fuse Protected Dosing Contacts
The relay dosing contact is rated for up to a 2A load and is fuse protected.
Labeled Termination Connections
Quick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.
1/2'' NPT Male Threaded Amperometric Probe for Mounting In-line*
The BL983329 mini controller uses the HI7634 conductivity probe that is available with different cable lengths.
*HI7634 is not included and must be ordered separately
SKU | BL983329-web |
---|---|
Product Name | TDS Mini Controller (0 to 999 ppm) - BL983329 |
Quote Required | Yes |
TDS Range | 0 to 999 ppm (mg/L) |
TDS Resolution | 1 mg/L ppm (mg/L) |
TDS Accuracy | ±2% f.s. |
TDS Calibration | manual, with CAL trimmer |
EC/TDS Temperature Compensation | automatic from 5 to 50°C (41 to 122°F) with β =2%/oC |
EC to TDS Conversion Factor | 0.5 |
EC/TDS Dosing Relay | maximum 2A (fuse protected), 250 Vac, 30 VDC |
EC/TDS Dosing Set Point | adjustable from 0 to 999 mg/L (ppm) |
Dosing Control | contact closed when measure > setpoint |
Over Dosing Control | adjustable, typically from 5 to approximately 30 minutes |
Power Supply | models “-0” |
Dimensions | 83 x 53 x 99 mm (3.3 x 2.1 x 3.9’’) |
Weight | models “-0” |
Ordering Information | BL983329-1 (115/230 VAC) and BL983329-0 (12 VDC) are supplied with mounting brackets, transparent cover and instruction manual. |