BL983313-1 Conductivity Mini Controller (0 - 1999 ¦ÌS/cm)

Previous 5 / 16 Next

Quantity
Add Quotation


Download Files

manbl983313_09_22_web.pdf (708.47 KB)

The BL983313 is a compact, panel mounted, process controller for measuring electrolytic conductivity (EC) of a process stream that is within the 0 to 1999 μS/cm range. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a dosing pump or a solenoid that controls a valve.

Multicolor LED Indicator

LED changes color based on status.

Fire Retardant Casing

For additional safety the controllers outer case is made of fire resistant plastic.

Splash Resistant Cover

A clear plastic cover protects the face panel from dirt and liquids.

 

This compact, panel mounted, process controller is for measuring electrolytic conductivity (EC) of a process stream. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point.

HI983313's relay can be used to activate a dosing pump or a solenoid that controls a valve.

HI983313 is ideal for source water or rinse water applications.


BL983313

Adjustable Dry Contact Dosing Relay

The BL983313 features a dosing relay that is activated when the reading is above a user programmable set point.

Programmable Overdose Protection

For enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.

Relay Control Override

With the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.

Multicolor LED Indicator

Multicolor LED indicator allows an operator to quickly check the status of the controller.

  • Green = Meter in measurement mode and reading is below the set point.
  • Orange/Yellow = Reading is above the set point and the relay is activated.
  • Blinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.

 

 

 


BL983313

Fuse Protected Dosing Contacts

The relay dosing contact is rated for up to a 2A load and is fuse protected.

Labeled Termination Connections

Quick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.

  • Model BL983313-2 is available with 4-20 mA Galvanic Isolated Output with external dosing disable contact
  • Large Clear LCD
  • Fire Retardant Casing
  • Splash-Resistant Cover

 

 

 

 

 


HI7634

1/2'' NPT Male Threaded Amperometric Probe for Mounting In-line*

The BL983313 mini controller uses the HI7634 conductivity probe that is available with different cable lengths.

*HI7634 is not included and must be ordered separately

 

 

 

 

 

 

 

 

 


BL931700

Front View

Installation cut-out dimensions are provided as well as outside panel dimensions.

BL931700

Side View

Adjustable location brackets allow the controller to slide easily and securely into place.
 

 

SKU BL983313-web
Product Name Conductivity Mini Controller (0 - 1999 μS/cm) - BL983313
Quote Required Yes
Range 0 to 1999 µS/cm
Resolution 1 µS/cm
Accuracy ±2% f.s. at 25 °C (77 °F)
Temperature Compensation automatic from 5 to 50°C (41 to 122°F) with β =2%/ºC
Calibration manual, with calibration trimmer
Output galvanic isolated 4-20 mA output; accuracy ±0.2 mA;
Output 500 Ω maximum load (BL983313-2 only)
Dosing adjustable setpoint covers measure range
Dosing relay relay closes when reading > setpoint
Dosing dosing contact maximum 2A (internal fuse protection),250 VAC or 30 VDC
Dosing overtime Dosing relay is disabled if setpoint is not reached within the set time interval. Timer adjustable between approx. 5 to 30 minutes, or disabled by jumper.
Dosing external disable input Normally Open
Power Supply models “-0” - 12 VDC adapter (included)
Power Supply models “-1” 115/230 VAC; 50/60Hz
Power Supply models “-2”
Power Supply input
Dimensions 83 x 53 x 99 mm (3.3 x 2.1 x 3.9’’)
Weight 12 VDC models, 200 g (7.1 oz); 115/230 VAC models 300 g (10.6 oz)