Visit
Official Website
0

Hanna Instruments (M) Sdn Bhd
11A, Jalan PJS 11/20,
Bandar Sunway,
46150 Petaling Jaya,
Selangor, Malaysia.
+603-5638 9940

Penang Branch Office
Hanna Instruments (M) Sdn Bhd
N0. 303-2-27, Krystal Point,
Jalan Sultan Azlan Shah,
11900 Sungai Nibong,
Penang, Malaysia.
+604-638 4558
+604-645 4558
penang@hannamalaysia.com

Sabah Branch Office
Hanna Instruments (M) Sdn Bhd

No. 4-1, 1st Floor,
Plaza Kingfisher,
Jalan Plaza Kingfisher 5,
Inanam, 88450 Kota Kinabalu,
Sabah, East Malaysia.
088-382 941
088-382 942
sabah@hannamalaysia.com


HI84533-60 Hydrogen Peroxide Reagent for Formol Number Mini Titrator

Previous 5 / 6 Next

Quantity
Add Quotation


Download Files

us_hi84533_60_ghs_usa_1.pdf (440.06 KB)
The HI84533-60 is a 30 mL bottle of hydrogen peroxide reagent that is used for samples on the HI84533 Formol Number Mini Titrator for Wine and Fruit Juice Analysis.

 

The HI84533 mini titrator is designed to determine both low and high range values of formol number in wine and fruit juice. Wine or fruit juice samples containing high levels of sulfur dioxide (SO2) may introduce error in determining formol number. With such samples, it is necessary to add several drops of HI84533-60 hydrogen peroxide reagent to neutralize the SO2 prior to titration.

  • Pre-measured solution
  • Clearly marked expiration date and lot number
  • Air tight bottle with tamper-proof seal

Details

The HI84533-60 is a 30 mL bottle of hydrogen peroxide reagent that is necessary for wine and fruit juice samples that contain high levels of SO2. The reagent neutralizes SO2 present and ensures an accurate determination of formol number.

The content of amino acids and other nitrogen compounds in wine or fruit juice is determined by an acid base titration to a fixed pH endpoint and expressed as total assimilable nitrogen. The determination of formol number is possible only after neutralization of the titratable acids present by a pH adjustment with HI84533-62 reagent, followed by the blockage of the amino groups by reaction with the HI84533-61 formol base reagent. The titration is then performed with the HI84533-50 titrant solution.

Replacement reagents required to operate the HI84533 include:
 

 

Low Range - 30.0 to 400.0 mg/L as N

High Range - 300 to 1000 mg/L as N

Pump calibration standard

HI84533-55

HI84533-55

Titrant solution

HI84533-50

HI84533-50

pH adjustment reagent

HI84533-62

HI84533-62

Formol base reagent

HI84533-61

HI84533-61

Hydrogen Peroxide reagent

HI84533-60

HI84533-60

 

 

 

Specifications

Package bottles
Size 30 mL
Quantity 1

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Messages*  
   

You have 0 items in you cart. Would you like to checkout now?
0 items
Recent Updates
Subscribe Newsletter