HI98192 Waterproof Portable EC/TDS/Resistivity/Salinity Meter
Previous | 1 / 6 | Next |
HI98192 Waterproof Portable EC/TDS/Resistivity/Salinity Meter
The HI98192 is a rugged, portable EC/TDS/Resistivity/Salinity meter with the performance and features of a benchtop. This professional, waterproof meter complies with IP67 standards. The HI98192 is supplied complete with all accessories to perform an EC/TDS/ Resistivity/Salinity measurement packaged into a durable carrying case.
- Four Ring Probe
- Quick Connect
- Ergonomic, One-Handed Operation
The HI98192 is supplied with the HI763133 four-ring conductivity probe with a built-in temperature sensor. This technology allows for accurate readings that cover a complete range with a single sensor. The four ring technology also eliminates the polarization effect that is common with standard two pole versions. The HI763133 conductivity probe connects to the meter with a unique quick connect waterproof DIN connector allowing for a secure attachment without a threaded connection that is also easy to remove.
HI98192 has an expanded conductivity range from 0.000 μS/cm to 1000 mS/cm actual conductivity (400 mS/cm temperature compensated). The HI98192 also has ranges for TDS, resistivity, and three salinity scales. This meter automatically recognizes the probe type (two or four ring) and allows the user to adjust the nominal cell constant.
HI98192 can be used to perform all three stages of USP method required for EC measurement of ultrapure water and generates a report when the any of the three stages are met.
Choose from seven memorized standards and obtain up to a five point conductivity calibration. For salinity (% range), HI7037 standard allows users to make a one point calibration.
EC and TDS measurements are fully customizable and include:
- Cell constant selection between 0.0 and 10.000
- Selection of linear or non-linear (natural water), or No temperature compensation
The temperature compensation coefficient range is configurable from 0.00 to 10.00%/°C with a choice of reference temperatures of 15°C, 20°C and 25°C. The conductivity to TDS factor is adjustable from 0.40 and 1.00.
The HI98192 allows for the creation of 10 measurement profiles with various user settings including temperature compensation, range selection, cell constant, and TDS conversion factors.
The log-on-demand mode allows the user to record and save up to 400 readings while the lot logging at selected intervals can store up to 1000 readings. This data can then be transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software.
GLP data includes date, time, standards used, temperature compensation used, reference temperature, and TDS conversion factor (TDS) is directly accessible by pressing the dedicated GLP key.
Access help at any time at the press of a dedicated button and view content specific information based on the screen that is currently being viewed.
The compact, durable HI720192 carry case is thermoformed to hold all necessary components for taking a field measurement, including the meter, probe, beakers and conductivity standards.
On-screen Features
Three stages of conformity
Performs all 3 stages of USP water quality testing requirements.
On-screen guide
Users are provided with on-screen instructions for each USP stage
Progress bar
Displays progress towards meeting stage 2 stability requirements.
Features/Benefits:
Compact, rugged, waterproof (IP67) design
Methods
- USP <645> capable for checking the quality of water used in pharmaceutical manufacturing
Salinity readings
- Seawater salinity can be displayed as % NaCl, natural seawater scale (ppt) or practical salinity scale (PSU)
Auto-ranging and fixed range options
Calibration
- Perform up to a five point calibration for enhanced accuracy
GLP Features
- GLP data provides calibration data including date, time, standards used, temperature compensation used, reference temperature, and TDS conversion factor (TDS)
Calibration timeout to alert the user at a defined interval when the calibration has expired
Auto Hold
- Freezes first stable reading on the display
Multiple language selection
Temperature compensation
- No temperature compensation, linear temperature compensation and non-linear temperature compensation – ISO/DIN 7888
- Configurable linear temperature compensation coefficient range from 0.00 to 10.00%/°C
Data logging
- Log on Demand: Store measurement data at the press of a button
- Interval lot logging: Log measurements at a selectable interval
Connectivity
- PC connectivity via opto-isolated USB with optional HI92000 software
100-hour battery life
- Approximately 100 hours of continuous use (without backlight)
Menu driven for ease of use with virtual-key extended functionality
Contextual help at the press of a button
Backlit, Graphic LCD
Connectivity
- PC connectivity via a sealed opto-isolated micro USB and HI92000 software
PRIMARY APPLICATIONS: Environmental, pharmaceutical, plating, water treatment, food manufacturing, and water and wastewater
SKU | HI98192 |
---|---|
Product Name | Waterproof Portable EC/TDS/Resistivity/Salinity Meter - HI98192 |
Quote Required | Yes |
EC Range | 0.000 to 9.999 μS/cm*; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to 400 mS/cm) |
EC Resolution | 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm |
EC Accuracy | ±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater) |
EC Calibration | automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) |
TDS Range | 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L) |
TDS Resolution | 0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L) |
TDS Accuracy | ±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater) |
EC/TDS Temperature Compensation | noTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear - ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F) |
Temperature Correction Coefficient | 0.00 to 10.00 %/°C |
EC to TDS Conversion Factor | 0.40 to 1.00 |
Reference Temperature | 15°C, 20°C and 25°C |
EC/TDS Multi-range Measurement Modes | autorange, autoend, lock and fixed range |
Salinity (% NaCl) Range | 0.0 to 400.0% |
Salinity (% NaCl) Resolution | 0.1% |
Salinity (% NaCl) Accuracy | ±1% of reading |
Salinity (% NaCl) Calibration | max. one point only in % range (with HI7037 standard) |
Salinity (PSU) Range | 0.00 to 42.00 (PSU) |
Salinity (PSU) Resolution | 0.01 PSU |
Salinity (PSU) Accuracy | ±1% of reading |
Salinity (PSU) Calibration | based on conductivity calibration |
Salinity Range | 0.00 to 80.00 (ppt) |
Salinity Resolution (ppt) | 0.01 ppt |
Salinity Accuracy (ppt) | ±1% of reading |
Salinity Calibration (ppt) | based on conductivity calibration |
Resistivity Range | 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm |
Resistivity Resolution | 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm* |
Resistivity Accuracy | ±1% of reading (±10 Ω or 1 digit, whichever is greater) |
Temperature Range | -20.0 to 120.0°C (-4.0 to 248.0°F) |
Temperature Resolution | 0.1°C (0.1°F) |
Temperature Accuracy | ±0.2°C; ±0.4°F (excluding probe error) |
EC/TDS Probe | HI763133, four ring conductivity/TDS probe with internal temperature sensor and 4 m (13.2’) cable (included) |
Logging Type | Log-on-demand |
Logging Memory | up to 10 |
Connectivity | opto-isolated USB with optional HI 92000 software and micro USB cable |
Automatic Shut-Off | user selectable |
Battery Type/Life | 1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight |
Environment | 0 to 50°C (32 to 122°F); RH 100% (IP67) |
Dimensions | 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) |
Weight | 400 g (14.2 oz.) |
Ordering Information | HI98192 is supplied with HI763133 conductivity probe, HI7031M 1413 μS/cm calibration solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case. |
Notes | *The 0.001 μS/cm EC range and 0.1 MΩ•cm not available with supplied probe |