HI8734 Three Range Portable TDS Meter
Previous | 6 / 6 | Next |
The HI8734 is a rugged, portable TDS meter designed for the water conditioning industry, particularly in the softening, demineralization, reverse osmosis, and drinking water applicaitons. It can also be used for a wide variety of environmental conditions. TDS readings are adjusted with manual temperature compensation, assuring users of consistent and accurate measurements of total dissolved solids.
- Four-ring probe
- measurement ranges from 0.0 mg/L to 19.99 g/L with a ±1% FS accuracy
- Manual Temperature Compensation
Features
Manually calibrated at one point in a standard TDS solution
Three dedicated-range buttons to easily change range
Meter communicates if reading is out of range and a new range should be selected
The HI8734 has a set TDS factor of 0.5, meaning that 1 μS/cm is equal to 0.5 mg/L (ppm) of TDS.
The temperature compensation coefficient, β, is set at 2%/°C, correcting the reading 2% for each degree Celsius change in the sample.
The HI76301D four-ring probe that is supplied with the meter allows for a wide range of measurements with a single sensor
The probe comes with a protective PVC sleeve that assures durability when taking measurements outdoors.
SKU | HI8734 |
---|---|
Product Name | Three Range Portable TDS Meter - HI8734 |
Quote Required | Yes |
TDS Range | 0.0 to 199.9 mg/L (ppm); 0 to 1999 mg/L (ppm); 0.00 to 19.99 g/L (ppt) |
TDS Resolution | 0.1 mg/L (ppm); 1 mg/L (ppm); 0.01 g/L (ppt) |
TDS Accuracy | ±1% FS (excluding probe error) |
TDS Calibration | manual, one-point through TDS knob |
EC/TDS Temperature Compensation | manual from 0 to 50°C (32 to 122°F) with β = 2%/°C |
EC to TDS Conversion Factor | 0.5 |
EC/TDS Probe | HI76301D four ring conductivity probe with DIN connector and 1 m (3.3’) cable (included) |
Battery Type/Life | 9V / approximately 100 hours of continuous use |
Environment | 0 to 50°C (32 to 122°F); RH max 95% |
Dimensions | 145 x 80 x 36 mm (5.7 x 3.1 x 1.4”) |
Weight | 230 g (8.1 oz) |
Ordering Information | HI8734 is supplied with HI76301D conductivity probe, HI70032 1382 mg/L (ppm) calibration solution sachet, battery, and instruction manual. |