Hanna Instruments (M) Sdn Bhd
11A, Jalan PJS 11/20,
Bandar Sunway,
46150 Petaling Jaya,
Selangor, Malaysia.
Penang Branch Office
Hanna Instruments (M) Sdn Bhd
N0. 303-2-27, Krystal Point,
Jalan Sultan Azlan Shah,
11900 Sungai Nibong,
Penang, Malaysia.
+604-638 4558
+604-645 4558
penang@hannamalaysia.com
Sabah Branch Office
Hanna Instruments (M) Sdn Bhd
No. 4-1, 1st Floor,
Plaza Kingfisher,
Jalan Plaza Kingfisher 5,
Inanam, 88450 Kota Kinabalu,
Sabah, East Malaysia.
088-382 941
088-382 942
sabah@hannamalaysia.com
HI9142 Portable Dissolved Oxygen Meter
Previous | 5 / 5 | Next |
The HI9142 is a rugged, portable, waterproof dissolved oxygen (DO) meter, with replaceable polytetrafluoroethylene (PTFE) membrane caps and protective shield, designed to provide reliable measurements under harsh environmental conditions. The HI9142 is supplied complete with polarographic probe, PTFE membrane caps, electrolyte fill solution, protective shield, and rugged carrying case.
- Easily Replaceable Membrane Caps
- Waterproof
- One or Two Point Calibration
Features
Replaceable, pretensioned, polytetrafluoroethylene (PTFE) membranes with a screw cap design for simple filling of electrolyte and easy replacement.
Polarographic measuring system based on the Ross and Clark polarographic measurement method
The probe uses a platinum cathode and silver anode in an electrolyte solution using external voltage to establish a current proportional to the concentration of dissolved oxygen
Manual one or two point calibration at 100% and automatic calibration in zero oxygen solution
A high-accuracy, built-in linearized thermistor temperature sensor behind a stainless steel cover
All readings are automatically compensated for temperature variations
SKU | HI9142 |
---|---|
Product Name | Portable Dissolved Oxygen Meter - HI9142 |
Quote Required | Yes |
Dissolved Oxygen Measurement Type | polarographic |
Dissolved Oxygen Range | 0.0 to 19.9 mg/L (ppm) |
Dissolved Oxygen Resolution | 0.1 mg/L (ppm) |
Dissolved Oxygen Accuracy | ±1.5% F.S. |
Dissolved Oxygen Calibration | manual in 100%; automatic in 0% DO |
Dissolved Oxygen Temperature Compensation | automatic, 0 to 50°C (32 to 122°F) |
Temperature Range | -5.0 to 50.0°C (23.0 to 122.0°F) |
Temperature Resolution | 0.1°C (1°F) |
Temperature Accuracy | ±0.2°C (±1°F) (excluding probe error) |
DO Probe | HI 76407 with 4 m (13') cable (included) |
Automatic Shut-Off | After approx. 8 minutes |
Battery Type/Life | 1.5V AA (4) / approx. 500 hours of use |
Environment | 0 to 50°C (32 to 122°F); RH max 100% |
Dimensions | 196 x 80 x 60 mm (7.7 x 3.1 x 2.4'') |
Weight | 500 g (1.1 lb.) |
Ordering Information | HI9142 is supplied complete with HI76407 DO probe, HI76407A/P pre-formed PTFE DO membranes (2), HI7041S electrolyte solution (30 mL), batteries, instructions and rugged carrying case. |