Hanna Instruments (M) Sdn Bhd
11A, Jalan PJS 11/20,
Bandar Sunway,
46150 Petaling Jaya,
Selangor, Malaysia.
Penang Branch Office
Hanna Instruments (M) Sdn Bhd
N0. 303-2-27, Krystal Point,
Jalan Sultan Azlan Shah,
11900 Sungai Nibong,
Penang, Malaysia.
+604-638 4558
+604-645 4558
penang@hannamalaysia.com
Sabah Branch Office
Hanna Instruments (M) Sdn Bhd
No. 4-1, 1st Floor,
Plaza Kingfisher,
Jalan Plaza Kingfisher 5,
Inanam, 88450 Kota Kinabalu,
Sabah, East Malaysia.
088-382 941
088-382 942
sabah@hannamalaysia.com
HI749 Low Range Chromium VI Colorimeter 每 Checker® HC
Previous | 17 / 40 | Next |
The Hanna Chromium VI Low-Range Checker (HI749) tests for the presence of Chromium VI (Hexavalent Chromium) in concentrations within the range of 0 to 300 ppb with an accuracy of ±3 ppb in samples such as drinking water and wastewater. With a digital readout, Hanna Checkers provide greater measurement accuracy when compared with chemical test kits that rely on human perception of color.
- Compact, Portable Design
- Built-in Timer
- One-Button Operation
The HI749 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure chromium VI. Due to its corrosion-resistant properties, hexavalent chromium plays an important part in the plating industry and cooling towers. However, due to its toxic and carcinogenic nature, chromium VI must be must be sufficiently treated prior to wastewater discharge. Designed as a more accurate alternative to chemical test kits, the HI749 provides quick, accurate results in four easy steps:
Features at-a-glance:
- Easier to use and more accurate than chemical test kits
- Dedicated to a single parameter
- Small size, big convenience
- Ideal for: Water Quality, Education, Industrial, Municipal Water
SKU | HI749 |
---|---|
Product Name | Chromium VI Low-Range Checker/Tester - HI749 |
Quote Required | Yes |
Chromium, Hexavalent Range | 0 to 300 ppb |
Chromium, Hexavalent Resolution | 1 ppb |
Chromium, Hexavalent Accuracy | ±3 ppb ±5% of reading |
Chromium, Hexavalent Method | adaptation of the ASTM, Manual of Water and Environmental Technology, D 1687-92, Diphenylcarbohydrazide method. |
Photometer/Colorimeter Light Source | LED @ 525 nm |
Photometer/Colorimeter Light Detector | silicon photocell |
Battery Type/Life | (1) 1.5V AAA |
Automatic Shut-Off | after ten minutes of non-use |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Weight | 64 g (2.25 oz.) |
Dimensions | 81.5mm x 61mm x 37.5mm (3.2'' x 2.4'' x 1.5”) |
Ordering Information | HI749 Checker® is supplied with (2) sample cuvettes with caps, chromium VI LR reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide. |