Visit
Official Website
0

Hanna Instruments (M) Sdn Bhd
11A, Jalan PJS 11/20,
Bandar Sunway,
46150 Petaling Jaya,
Selangor, Malaysia.
+603-5638 9940

Penang Branch Office
Hanna Instruments (M) Sdn Bhd
N0. 303-2-27, Krystal Point,
Jalan Sultan Azlan Shah,
11900 Sungai Nibong,
Penang, Malaysia.
+604-638 4558
+604-645 4558
penang@hannamalaysia.com

Sabah Branch Office
Hanna Instruments (M) Sdn Bhd

No. 4-1, 1st Floor,
Plaza Kingfisher,
Jalan Plaza Kingfisher 5,
Inanam, 88450 Kota Kinabalu,
Sabah, East Malaysia.
088-382 941
088-382 942
sabah@hannamalaysia.com


HI3618D Glass Body ORP Electrode with DIN Connector

Previous 9 / 11 Next

Quantity
Add Quotation


The HI3618D is a glass body, refillable, single junction ORP electrode with a DIN connector. This electrode has a single ceramic junction in the outer reference cell and the ORP sensing pin is made with platinum.

 

This electrode features a built-in temperature sensor to ensure temperature compensated measurements in a single probe design. This design consideration is ideal for laboratories and general purpose ORP measurements.

  • Built-In Temperature Sensor
  • Refillable Electrode
  • Platinum Sensing Pin

Details

Hanna Instruments offers a wide variety of ORP electrodes that are designed for many different applications. The type of material used for the sensing pin, type of glass used for body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The HI3618D uses a platinum pin, glass body, single ceramic junction and is refillable with 3.5M KCl + AgCl.



Platinum Sensing Pin

The HI3618D ORP sensor is made with platinum. An ORP sensor must be chemically inert; it cannot be oxidized or reduced itself. It must also have the proper surface characteristics to promote rapid electron  exchange, a property known as high exchange current density. Two noble metals have proven to work well for this purpose: pure platinum and pure gold are both used in the construction of ORP sensors. The platinum sensor is often preferred because it is mechanically simpler and safer to produce. Platinum can be welded to glass and has the same thermal coefficient. The platinum sensor signal is carried through the electrode body, and together with the reference signal is conducted to the measurement meter.

 



Glass Body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the electrode reaches equilibrium, the steadier the reference potential.

 



Single Ceramic Junction

The outer junction of an electrode, also known as a salt bridge, is necessary component of the electrical circuit. The movement of ions must flow through the junction for a steady reading. The outer reference has a single ceramic frit. The ceramic is a porous material that is easily fused with the glass body and has a similar expansion coefficient. A single ceramic junction has a flow rate of 15-20 μL/hour. Other junction types are available with higher flow rates and made with different materials.

 



Refillable

The HI3618B is a refillable probe. Since it is a single junction ORP electrode the fill solution is the HI7071 3.5M KCl + AgCl. If using a refillable ORP electrode, the fill cap should be removed prior to measurement. Removing the cap creates positive head pressure in the reference cell allowing for higher flow rate of electrolyte through the outer junction. A higher flow rate will result in a faster and more stable reading.

 



DIN Connector

The HI3618D uses a DIN connector. This type of connector is generally proprietary to the meters they are supplied with and may not be interchangeable. Other type of connectors include BNC, screw type, T-type, and 3.5mm to name a few.

Specifications

Body Material glass
Reference single, Ag/AgCl
Junction / Flow Rate ceramic, single / 15-20 μL/h
Electrolyte 3.5M KCl + AgCl
Range ORP: ±2000 mV
Max Pressure 0.1 bar
Tip Shape platinum pin
Diameter 12 mm
Body Length / Overall Length 120 mm / 175.5 mm
Recommended Operating Temperature -5 to 70°C (23 to 158°F)
Temperature Sensor yes
Matching Pin no
Amplifier yes
Digital no
Cable 5-pole; 1 m (3.3')
Connection DIN
Applications laboratory general purpose

 



 

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Messages*  
   

You have 0 items in you cart. Would you like to checkout now?
0 items
Recent Updates
Subscribe Newsletter