*HI96718-11 Iodine CAL Check™ Standards - HI96718-11

Previous 55 / 99 Next

Quantity
Add Quotation


Download Files

us_hi96718b_ghs_usa_2.pdf (504.33 KB)

The HI96718-11 Iodine CAL Check Standards provide a simple solution to calibrating and validating compatible portable photometers. This high quality set of standards is manufactured in our state-of-the-art facility and comes supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiration date for traceability when certifying compatible iodine photometers.

Supplied with Certificate of Analysis

Standard value of 2.5 ±0.2 mg/L iodine @ 25°C

Reusable with long shelf life stability

Details

HI96718-11 is a high quality set of calibration standards that allows users to validate and calibrate the iodine range found in compatible photometers that have a 0.0 to 12.5 mg/L (ppm) iodine range. The HI96718-11 includes one sealed “A” cuvette for zeroing the meter and one “B” cuvette that is used to validate or calibrate. The expected reading from the “B” standard is 2.5 ±0.2 mg/L iodine @ 25°C. The calibration set is produced in our state-of-the-art manufacturing facility using reagent grade chemicals in a temperature controlled environment.

 

Supplied with Certificate of Analysis

  • Product code

  • Lot number

  • Expiration date

  • Standard value @ 25°C

  • Reference meter NIST traceable

 

Provided storage containers

  • Light tight

  • Protects from accidental breakage

 

Compatible meters:

  • HI96101

  • HI96718



Validation and calibration of iodine for one of the portable photometers listed above is quick and easy with the HI96718-11 Cal Check Standards

 

cal check

 

Specifications

Package sealed standards: 0.0 and 2.5 mg/L iodine
Quantity 1 set