*HI96714-11 Cyanide CAL Check™ Standards

Previous 51 / 99 Next

Quantity
Add Quotation


Download Files

us_hi96714b_ghs_usa_1.pdf (388.16 KB)
The HI96714-11 Cyanide CAL Check™ standards provide a simple solution to calibrating and validating the HI96714 Cyanide Portable Photometer. This high quality set of standards is manufactured in our state-of-the-art facility and comes supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiration date for traceability when certifying the HI96714 photometer.
  • Supplied with Certificate of Analysis
  • Standard value of 0.100 ±0.005 mg/L (ppm)
  • Reusable with long shelf life stability










Details

HI96714-11 is a high quality set of calibration standards that allows users to validate and calibrate the HI96714 Cyanide Portable Photometer. The HI96714-11 includes one sealed “A” cuvette for zeroing the meter and one “B” cuvette that is used to validate or calibrate. The standard value of the “B” cuvette is 0.100 ±0.005 mg/L (ppm). An acceptable reading when validating the HI96714 with the standards is 0.100 ±0.010 mg/L @ 25°C.  The calibration set is produced in our state-of-the-art manufacturing facility using reagent grade chemicals in a temperature controlled environment.  

 

Supplied with Certificate of Analysis

  • Product code

  • Lot number

  • Expiration date

  • Standard value @ 25°C

  • Reference meter NIST traceable

 

Provided storage containers

  • Light tight

  • Protects from accidental breakage

 

Validation and calibration of the cyanide range for the HI96714 portable photometer is quick and easy with the HI96714-11 CAL Check Standards.

 

 

Specifications

Package sealed standards: 0.000 and 0.100 mg/L cyanide
Quantity 1 set




















Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Messages*  
   

You have 0 items in you cart. Would you like to checkout now?
0 items
Recent Updates
Subscribe Newsletter