Hanna Instruments (M) Sdn Bhd updated website's banner
Feb 22, 2023 at 11:54 am —
Hanna Instruments (M) Sdn Bhd updated website's banner
Feb 22, 2023 at 11:53 am —
Hanna Instruments (M) Sdn Bhd added new photo in Process Control - Controllers & Transmitters
Feb 22, 2023 at 09:32 am —
HI510 Process Controller Universal

HI510 Process Controller Universal

RM 6,034.00

HI510 is designed to adapt to a user’s unique process control requirements. The controller has a large backlit dot matrix display for easy viewing and provides for an intuitive interface for setup options. The controller utilizes multi-color LEDs for easy viewing of the instruments’ status including relay activation, in alarm mode, or in hold status. All programming operations are done through the low profile vulcanized rubber keypad or using the RS485 connection to a PC operating the HI92500 Windows® compatible software.   Digital input for pH and ORP probes Up to 5 relays for control and cleaning sequence Up to 4 analog output for control and monitoring HI510 is an advanced universal process controller that can be configured for many applications requiring monitoring and/or control of process parameters. It features a digital probe input that will automatically detect and update the controller with the parameter that it measures. This controller can be configured with up to 5 control relays and 4 analog outputs. The control relays can be programmed for on/off, Proportional, or PID (Proportional Integral Derivative) types of control or used for programming cleaning sequences triggered by a digital input or based on a schedule. The scalable analog outputs can be used for remote devices including Chart recorders, PLC, or SCADA. The analog outputs can be used for control devices including dosing pumps and valves that accept a 0/4-20 mA output. HI510 features a RS485 digital output that allows up to 32 devices to be connected to a single line that can be viewed and programmed remotely using the HI92500 software. The HI92500software provides for graphic user interface that allows for settings to be changed and saved for transfer to another HI510 controller. The HI510 NEMA 4X enclosure uses sealed cable glands to maintain waterproof integrity. The versatile mounting kits allow for mounting the HI510 to a wall, pipe and panel.   General Design Features Backlit Dot Matrix LCD with LED indicators Large backlit LCD with visual indicators for meter status, alarm and relay activation. NEMA 4X Enclosure ½ DIN NEMA 4X enclosure suitable for outside and industrial environments. Versatile Mounting Options Choose from wall, pipe or panel mounted options. USB-C Connectivity Flash Drive Compatible Transfer of logged data and events to a flash drive as a .csv file for review on Window’s, OS X, or Linux based computers. Logged Data Store information at selectable intervals along with relay control settings and calibrations data. Information can be stored in up to 100 lots, each holding 8600 records. Event Management System Logged events includes any changes made, alarm, error and warning activations, and calibration information.   Low Voltage Connections Isolated High Voltage Section To reduce the risk to shock the low voltage connection area is isolated from high voltage area. RS485 Digital Connectivity RS485 output for connecting up to 32 devices for remote monitoring and programming. Digital Inputs and Analog Outputs Digital probe input, digital trigger inputs, and analog outputs utilize extractable terminal blocks for simplified wiring. High Voltage Connections Replaceable Slow Blow Fuses All relays and the line power input are protected by replaceable 5A slow blow fuses. SPDT and SPST Programmable Relays Up to 5 relays that can be programmed for control or washing sequences. Fail Safe Alarm Technology Fail Safe Alarm Technology that deactivates relay from normal open state to normally closed to supply power to remote alarm device.   Programming HI510 remotely using HI92500 Software Relay Control Modes Set points for control operations can be configured to be on/off, proportional, or PID types of control. The flexibility in programming allows for fine-tuning of a set point to be maintained with tight control preventing any overshoot and waste of chemicals. Configurable Alarm System Configurable for set points and temperature or activated by abnormal operation, a red Alarm LED will blink and can easily be seen from a distance. All relays configured for control are inactivated until the alarm state is resolved. Auto-cleaning cycle The cleaning function allows the ability to program one or more wash cycles and use the relays to activate valves, pumps or compressed air based on the type of washing that is required to maintain probes for reliable results. Scalable Analog Outputs Analog outputs can be scaled to assign 0 to 20 mA or 4-20 mA to a specific range for increased resolutions. Analog outputs can be programmed to send 22 mA signal when placed in hold status during maintenance including calibration. More Information More Information SKU HI510 Product Name Universal Process Controller - HI510 Quote Required No Dosing Control on/off, proportional and PID Dosing Terminals Up to 5 relays (independently configurable for process variables, Hold & Cleaning functions) Electromechanical relay SPDT and SPST contact outputs 5A – 250 Vac; 5A – 30 Vdc (resistive load) Fuse protected Alarm Relay Set Point Up to 5 relays (independently configurable for process variables, Hold & Cleaning functions) Electromechanical relay SPDT and SPST contact outputs 5A – 250 Vac; 5A – 30 Vdc (resistive load) Fuse protected Over Dosing Control yes System Error yes Analog Ouput Signal 2 or 4 independent, galvanically isolated outputs 0 – 22 mA configurable as Analog Ouput Accuracy ±2% full scale Digital Input Signal independent, galvanically isolated inputs (configurable for Hold & Cleaning functions) On state Digital Output Signal RS485 Backlight yes Power Consumption 15VA Enclosure *Single case ½ DIN, type NEMA4X, IP65 ingress protection Installation Category II Panel Cutout 1/2 DIN (brackets ordered seperately) Input Channels one digital input with RS485 interface pH Electrode HI10X6 series – pH and Temperature (ordered seperately) ORP Electrode HI20X4 series – ORP and Temperature (ordered seperately) Logging Type Interval log, up to 100 files, maximum 8600 records on each stored file. When the maximum limit of 100 stored files is reached, the most recent file will automatically erase the oldest one. Event log, maximum 100 records. When the maximum limit i Connectivity RS485 serial port - Remote monitoring and control USB-C port - Retrieve log files and firmware upgrading GLP yes Calibration Timeout Reminder yes Analog Output up to 4 based on configuration ordered Display Graphic LCD, 128 x 64 pixel B/W with backlight Power Supply 100 – 240 Vac ±10%; 50/60 Hz; 15VA; fuse protected (2A, 250V slow blow fuse) Environment -20 to 50 ºC (-4 to 122 ºF); maximum 100% RH non-condensing IP Rating IP65 Dimensions Width 144.0 mm (5.7”) x Height 144.0 mm (5.7”) x Depth 151.3 mm (6.0”) Weight Approximately 1.6 kg (3.5 lb.) Notes *For a water tight seal, tighten the front four screws on the front casing to 13.3 lbf·in (1.5 N·m, maximum 2.0 N·m), of torque. read more
Hanna Instruments (M) Sdn Bhd added new photo in Benchtop Meters - pH/ORP
Feb 22, 2023 at 09:22 am —
HI6221 Advanced pH/ORP Benchtop Meter

HI6221 Advanced pH/ORP Benchtop Meter

RM 4,986.00

HI6221 Advanced pH/ORP Benchtop Meter Laboratory Measure pH/mV (pH) or mV/Rel. mV (ORP) with Temperature HI6221 is a streamlined benchtop meter with a large touch screen display, comprised of a housing and an integrated pH / ORP measurement module. Compact and easy to operate, the benchtop meter is delivered with Hanna Instruments HI1131B double junction combination pH electrode, together with HI7662-TW temperature probe. HI1131B is a glass body, double junction, refillable pH electrode with an indicating sensor made of High Temperature (HT) glass. The double junction reference and HT glass design allow the HI1131B to be used in a wide variety of applications including samples with metals and elevated temperatures. Probe connection to the unit is secured through a galvanically isolated BNC connection. HI7662-TW stainless steel temperature probe allows the meter to automatically temperature compensate (ATC) pH measurements.     This system responds to a complex range of measurement and monitoring requirements, providing accuracy, reproducibility, and reliability. HI6221 is supplied with an electrode holder that has a flexible arm. The holder can be mounted quickly and provides secure support for electrodes while taking measurements in sample containers. User interface 7-inch capacitive touch screen with multi-touch support Capacitive touch back, home and system menu keys User-friendly icons and symbols allow users to easily navigate and interpret the instrument functions. The user can select between five different views: Basic measurement configuration Simple GLP with calibration information Full GLP with electrode status and calibration point details Live updated, interactive graph Tabulated data with date, time, and notes Measurement Measure pH/mV (pH) or mV/Rel.mV (ORP) with temperature Application-specific profiles allow quick and direct measurement without the need to update the sensor and system settings Active log during measurement o Measurement stability indicator (using the Stability Criteria setting) Reading modes: direct and direct/autohold Temperature compensation can be Automatic (using temperature probe) or set manually Audible and/or alarm messages for measurements outside of predefined limits Galvanic isolation for pH/ORP measurement Calibration 5-point pH calibration with automatic recognition for standard buffers (Hanna and NIST buffers) Choice of standard or custom buffers for calibration Non-volatile memory saves data and settings Logging Data log collection of at least 1,000,000 data points (with time and date stamp) Logging types: manual, automatic, autohold Sample ID for manual and Autohold data Connectivity features & services Transfer logged data to a USB thumb drive Log files that include measurements and calibration data (as .csv file) FTP and email for log export via Ethernet and Wi-Fi connection USB type A for USB stick, keyboard, and printer USB type C for USB stick and PC connection Help section for meter guidance Video support presentation of main functionalities     Customize calibration options such as Last Calibration, Automatic, semi-automtic or manual calibration, First Calibration Point, daily or periodic Calibration Reminder, and buffer Groups.     Capacitive touch screen with multi-touch support The benchtop unit has a 7-inch color display with 800 x 480p resolution. The capacitive, multi-touch screen supports video playback and data plotting. System Menu key This key will enter the system menu where User accounts, System Settings, and Logging can be configured. The Help menu is also accessed on the system menu screen. Measurement setup menu Opens sensor setup parameters. Direct/Autohold readings When Direct/Autohold is selected, measurement reading is held on display when measurement stability is reached. This option removes the subjective nature of stability as a measurement that has not reached equilibrium will not be used. When not selected, sample measurements are displayed continuously.   HI6221 is supplied with: HI1131B pH electrode; HI7662-TW temperature probe pH calibration starter kit consisting of: pH 4.01 buffer solution sachet (2 pcs.) pH 7.01 buffer solution sachet (4 pcs.) pH 10.01 buffer solution sachet (2 pcs.) HI700601 electrode cleaning solution sachet (2 pcs.) HI7082 3.5M KCl electrolyte solution (30 mL) HI764060 electrode holder Capillary pipette 24 VDC power adapter USB-C to USB-A cable Quick reference guide with instrument quality certificate.     More Information SKU HI6221 Product Name Advanced pH/ORP Benchtop Meter- HI6221 Quote Required Yes pH Range -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to pH Range 20.000 pH pH Resolution 0.1 pH; 0.01 pH; 0.001 pH pH Accuracy ±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit) mV Range ±2000.0 mV mV Resolution 1 mV; 0.1 mV mV Accuracy ±0.2 mV ±1 last significant digit Temperature Range -20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K Temperature Resolution 0.1 °C / 0.1 °F / 0.1 K Temperature Accuracy ±0.2 °C / ±0.4 °F / ±0.2 K Relative mV offset range ±2000.0 mV pH Calibration Calibration points Up to 5 pH Calibration Type Automatic; Semiautomatic; Manual pH Calibration Standard buffers Hanna and NIST pH Calibration Standard buffers pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45'' pH Calibration Custom buffers Up to 5 pH Calibration Custom group Up to 5 pH Calibration 1st calibration point Offset or Points (user setting) pH Calibration Reminder Disabled pH Calibration Reminder Daily pH Calibration Reminder Periodic Temperature Compensation Automatic or Manual Reading Modes Direct; Direct/Autohold Reading Stability criteria Accurate; Medium; Fast Reading Isopotential 7.000 or 4.010 Reading Sampling rate 1000 ms pH Views Basic Measurement (pH, mV, Rel.mV, Abs.mV) pH Views Basic Temperature, Stability status pH Views Simple GLP Basic view information pH Views Simple GLP Last calibration date, electrode offset, average slope, and electrode condition pH Views Full GLP Simple GLP information and calibration point details pH Views Table Measurements updated every second are displayed in table pH Views Graph (Plot) pH (or mV) and temperature versus time graph can be panned or zoomed (pinch-to-zoom technology) Logging Type Automatic, Manual, Autohold Logging Number of records 50 000 maximum per file / Stores at least 1 000 000 data points per user'' Logging Automatic interval 1, 2, 5, 10, 30 seconds Logging Automatic interval 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes'' Logging Sample ID Incremental mode Logging Export option .csv file format Logging Export option Users Up to 9 users and admin. account (default) Connectivity USB-A 2 ports for keyboard input or USB thumb drive Connectivity USB-C 1 port for PC connectivity and USB-C type thumb drive Connectivity Wi-Fi & Ethernet FTP / Web server Log transfer and download Email Connectivity RS232 Connecting peripherals Power supply DC adapter 100-240AC to 24VDC 2.5A Environment 0 - 50 °C / 32 - 122 °F / 273 - 323 K maximum 95% RH non-condensing Dimensions 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “) Weight Approximately 1.2 kg (2.65 lbs.)   read more
next page